Key Advantages & Features
1. AB-Circuit Redundancy: Zero-Downtime Guarantee: The dual AB-circuit design acts as a fail-safe. If Circuit A malfunctions (e.g., overload, short circuit), the PDU automatically switches to Circuit B, keeping connected equipment operational. This eliminates costly downtime, a must for mission-critical IT and industrial systems.
2. High-Density Outlet Configuration: 15 C13 (10A) outlets power standard devices (switches, routers), while 12 C19 (16A) outlets handle high-power gear (servers, storage arrays). This mix supports dense rack deployments, maximizing connectivity without the need for extra adapters or multiple PDUs.
3. Anti-Drop Locks for Secure Connections: Every C13/C19 outlet is fitted with a mechanical anti-drop latch. It locks plugs tightly to prevent disconnections from cable tugs, vibrations, or accidental bumps—ensuring consistent power delivery even in busy data centers or industrial environments.
4. Premium Conductivity with Tinned Copper Bars: 10-square tinned copper bars, joined via through-welding, minimize electrical resistance and corrosion. This design ensures over 99% power transmission efficiency, even at the 250V 80A rating, reducing heat buildup and extending the PDU’s lifespan.
5. Robust AB-Circuit OT Junction Box: The dedicated AB-circuit OT junction box provides secure, isolated connections for both circuits. Its rugged construction prevents cross-circuit interference and loose contacts, forming a reliable foundation for the redundant power system.
Product Uses
1. Enterprise Data Centers: Powers core server clusters for cloud services/big data, with AB redundancy ensuring uninterrupted operation during circuit maintenance or faults.
2. Financial Service Hubs: Supports trading systems and data servers, where even seconds of downtime are costly—AB circuits guarantee continuous power for critical transactions.
3. Industrial Control Rooms: Supplies power to PLCs and monitoring devices, with redundancy preventing production halts caused by single-circuit failures in manufacturing plants.
4. Hospital IT Departments: Runs medical record systems and diagnostic equipment, ensuring power continuity that complies with healthcare industry reliability standards.






Q1: How does the AB-circuit switch work - automatically or manually?
A1: It switches automatically within 0.1s when a circuit fails, ensuring seamless power continuity without manual intervention.
Q2: Is this PDU compatible with 250V single-phase grids?
A2: Yes, it's optimized for 250V single-phase commercial/industrial grids, matching the rated 80A current for stable performance.
Q3: Can I assign specific outlets to Circuit A or B?
A3: Yes, the PDU allows flexible outlet-circuit mapping. Contact our team to customize the configuration based on your equipment needs.
Q4: What's the max load per C19 outlet?
A4: Each C19 outlet supports up to 16A (4000W at 250V), suitable for high-power servers, storage arrays, and industrial equipment.