Key Advantages & Features
1. Anti-Drop Outlet for Uninterrupted Power: Every C13/C19 outlet is fitted with a mechanical anti-drop latch. Once plugged in, the latch secures the connector tightly, preventing accidental disconnections from cable tugs or vibrations—avoiding costly downtime for mission-critical equipment.
2. 3P Air Switch with Visible Safety Control: The integrated 3P air switch serves as a main power cutoff, with a bright LED indicator showing real-time power status (on/off). It triggers automatic tripping during overloads, providing rapid protection against electrical faults to safeguard both PDU and connected devices.
3. High-Power Capacity & Stable Transmission: Designed for 3-phase grids, it supports 41000W total load, easily powering dense server racks or industrial equipment. The 12.4-square high-conductivity copper bars minimize resistance and heat buildup, ensuring efficient power delivery even at full load.
4. Robust 63A Terminal Block: The 63A heavy-duty terminal block creates a secure, low-resistance connection to the 3-phase main supply. Its corrosion-resistant design prevents loose contacts and power fluctuations, forming a reliable foundation for the entire power distribution system.
5. Versatile Outlet Configuration: 8 C13 outlets (10A max) fit standard IT devices like switches and small servers, while 4 C19 outlets (16A max) handle high-power gear such as rack-mounted servers. This mix eliminates adapter needs for mixed-equipment setups.
Product Uses
1. Enterprise Data Centers: Powers dense server clusters running ERP, big data analytics, or cloud services, with anti-drop outlets ensuring uninterrupted operation during maintenance.
2. Industrial Manufacturing Hubs: Supplies power to heavy-duty PLCs, automated production lines, and monitoring systems, leveraging 3-phase stability to avoid production disruptions.
3. Colocation Facilities: Meets multi-tenant needs with versatile C13/C19 outlets, while the 3P switch allows easy power management for individual rack units.
4. Broadcasting Studios: Powers high-wattage video servers, transmission equipment, and editing workstations, ensuring stable power for live broadcasts or content production.






Q1: What's the difference between C13 and C19 outlets in terms of usage?
A1: C13 (10A) works for standard IT devices (routers, small servers); C19 (16A) is for high-power gear like large rack-mounted servers or storage arrays.
Q2: How to reset the 3P air switch after it trips?
A2: First fix the overload/fault cause, then push the switch's "Reset" button (if equipped) and flip it to "On". Ensure total load is under 41000W before restarting.
Q3: Is this PDU compatible with 380V 3-phase grids?
A3: Yes, it's optimized for 380V 3-phase industrial/commercial grids— the standard for data centers and manufacturing facilities, ensuring seamless integration.
Q4: Can the anti-drop latch be disabled if needed?
A4: No, the latch is a built-in safety feature. Disabling it would risk accidental disconnections. For special needs, contact us for customized outlet designs.