Key Advantages & Features
1. Balanced C13/C19 Outlet Configuration
With 6 C13 (10A) outlets for standard IT gear (switches, routers) and 8 C19 (16A) outlets for high-power devices (rack servers, storage arrays), this PDU fits mixed-equipment racks perfectly. It eliminates adapter clutter and maximizes connectivity, ideal for mid-to-high density power deployments.
2. 20KA Hot-Swappable Surge Protection
The 20KA-rated surge protection module defends against severe voltage spikes (up to 20,000 amps) common in industrial and data center grids. It supports hot swapping, allowing replacement without powering down the PDU—ensuring uninterrupted protection for mission-critical equipment.
3. Hot-Swappable Power Indicators for Easy Maintenance
The detachable power indicator module enables hot swapping, so you can inspect or replace it without disrupting power to connected devices. Bright LEDs provide real-time status visibility, simplifying quick troubleshooting of mixed C13/C19 setups in 24/7 operations.
4. 4-Square Welded Copper Bars for Efficient Transmission
4-square high-conductivity copper bars, joined via precision welding, minimize electrical resistance and heat buildup. Even at full 32A load, they ensure over 99% power transmission efficiency, preventing voltage fluctuations that could damage sensitive IT gear.
5. High Load Capacity for Dense Deployments
Rated 250V 32A (8000W total), this PDU handles the cumulative load of 6 C13 and 8 C19 outlets with ease. It avoids the need for multiple low-capacity PDUs, streamlining rack power infrastructure and reducing cable management complexity.
Product Uses
1. Mid-Size Enterprise Server Rooms
Powers a mix of C13-connected network switches and C19-rated file servers, with surge protection guarding against grid anomalies in office IT environments.
2. Industrial Control Rooms
Supplies power to C13 PLCs and C19 heavy-duty monitoring equipment, with stable copper bar transmission ensuring uninterrupted production workflows.
3. Colocation Facilities
Caters to multi-tenant mixed-power needs, with balanced outlets adapting to diverse client IT setups (standard routers + high-power servers).
4. Broadcasting Studios
Runs C13 editing workstations and C19 high-wattage video servers, with 20KA surge protection preventing broadcast disruptions from voltage spikes.






Q1: What’s the maximum load per C13/C19 outlet?
A1: Each C13 outlet supports 10A (2500W) and each C19 outlet 16A (4000W), with total PDU load capped at 32A (8000W) to avoid overloads.
Q2: How to replace the 20KA surge protection module?
A2: It supports hot swapping—simply unclip the old module and snap in a new one without shutting down the PDU, ensuring continuous power.
Q3: Is this PDU compatible with 220V single-phase grids?
A3: Yes, it works seamlessly with 220-250V single-phase grids, matching standard commercial/industrial power supplies in most regions.
Q4: Can the PDU be rack-mounted in standard server racks?
A4: Yes, it features a 1U rack-mount design with pre-drilled holes and included hardware, fitting 19-inch standard racks for space-efficient installation.