This UK 13A 8-Way Aluminium PDU Power Strip is designed for organised power distribution in home, office, and indoor environments. It features a durable 6063-T5 aluminium alloy housing, high-strength PC side covers, and an eco-friendly powder-coated black finish with green accents.
Equipped with 8 BS 1363-2 UK socket outlets, a BS 1363-1 13A UK plug, a green double-pole switch with cover, and an overload protection device, it provides convenient power control and basic overload protection for multiple connected devices. The PDU is rated at 250V AC, 13A Max and 50Hz, with a 1.5 mm² 3-conductor, 2 m power cord.
Featuring a 2U CN Series 45 mm profile and left-side cable entry, this PDU offers a compact and organised solution for everyday power distribution. The product is designed in accordance with applicable ISO technical requirements and UK electrical safety requirements, with UKCA conformity assessment requirements considered for the Great Britain market.
| Availability: | |
|---|---|
| Quantity: | |
(DMCN-2UT-E8-KG-1.5p2m-YB13A)-Green
PEDIU
PE20260828-352
The 2U CN Series UK PDU is a compact power distribution solution designed for UK office, commercial, workstation and equipment power applications. It features a 6063-T5 aluminium alloy housing, high-strength PC side cover, and eco-friendly powder coating, providing a practical and durable enclosure for professional power distribution.
Configured with 8 BS 1363-2 UK socket outlets, one green double-pole switch with protective cover, and an overload protection device, the PDU supports organised power distribution for multiple compatible UK electrical devices. With a 250V AC / 13A Max rating, 2 m power cord and left-side cable entry, it is suitable for applications where compact installation and standard UK socket compatibility are required.
Office Workstations and Desks
Commercial Offices
Conference Rooms and Meeting Spaces
Home Office Workstations
Educational Facilities
Coworking Spaces
Commercial Furniture
Professional Equipment Power Distribution
General Electrical Equipment
The PDU is equipped with an overload protection device. The total connected load must remain within the 13A maximum rated current to prevent operation beyond the product's rated capacity.
The unit provides 8 BS 1363-2 UK socket outlets, making it suitable for compatible equipment using the UK socket standard.
The green double-pole switch with protective cover provides a convenient power switching interface, while the cover offers additional protection for the switch during normal operation.
The 6063-T5 aluminium alloy housing provides a robust enclosure structure, while the eco-friendly powder-coated finish provides a consistent and clean product appearance.
Internal wiring is securely fastened and properly insulated, and electrical connections are securely terminated. Finished products are inspected before delivery according to applicable inspection requirements.
The product is designed to comply with applicable UK electrical safety requirements and relevant product regulations. It is designed to meet applicable UKCA conformity assessment requirements for the Great Britain market, with UKCA marking applied where required. Technical documentation and the applicable Declaration of Conformity are maintained as required.
For customers requiring customised PDU solutions, OEM and ODM services can be developed according to specific application and project requirements. Customisation options may include:
Housing dimensions and structural design
Housing and side-cover colours
UK socket quantity and configuration
Plug type and electrical configuration
Power cord specification and length
Switch type and configuration
Protection function configuration
Cable-entry position
Product appearance and surface finish
Packaging and product identification
Technical drawings and documentation
Equipped with eight BS 1363-2 UK socket outlets, this PDU provides multiple connection points for compatible electrical equipment. The 8-outlet configuration is suitable for organised power distribution across workstations, offices and other indoor environments.
A green double-pole switch with a protective cover provides a clear and accessible switching interface. The covered design complements the product's Green Series appearance while helping protect the switch during everyday use.
The integrated overload protection device helps protect the PDU during overload conditions. With a maximum rated current of 13A at 250V AC, the unit is designed to operate within its specified electrical capacity.
The main housing is manufactured from 6063-T5 aluminium alloy, providing a robust enclosure for the internal electrical components. High-strength PC side covers complete the product structure.
The main aluminium housing features a black eco-friendly powder-coated finish, combined with green PC side covers and a green switch. The consistent colour scheme creates a distinctive Green Series appearance for organised equipment environments.
The 2U CN Series profile has a height of 45 mm, providing a compact form factor for compatible PDU installations. The streamlined structure helps make efficient use of available installation space.
The left-side cable entry provides a defined cable routing direction, while the 2 m power cord offers practical connection length for compatible indoor installations.
Internal wiring is securely fastened and properly insulated, while electrical connections are securely terminated. Components are cleaned before assembly to support consistent manufacturing quality.
Finished products are inspected before delivery, including applicable dimensional, visual, assembly and electrical safety checks. Finished surfaces are protected during handling, packaging and transportation.
The PDU uses a BS 1363-1 13A UK plug and BS 1363-2 UK socket outlets and is designed according to applicable UK electrical safety requirements and relevant product regulations. For the Great Britain market, applicable UKCA conformity assessment requirements and technical documentation should be addressed according to the product's regulatory scope.
Combining eight UK socket outlets, a covered double-pole switch, overload protection and a durable aluminium housing, this Green Series PDU provides a practical solution for centralised indoor power distribution within its rated capacity.
Product Description
Specification | Details |
|---|---|
Product Category | Power Distribution Unit (PDU) |
Main Housing Material | 6063-T5 Aluminum Alloy |
Side Cover Material | High-Strength PC |
Surface Finish | Eco-Friendly Powder Coating |
Main Housing Color | Black |
Side Cover Color | Blue |
Profile | 2U CN Series |
Profile Height | 45 mm |
Rated Voltage | 250V AC |
Rated Current | 13A Max. |
Rated Frequency | 50Hz |
Plug Type | BS 1363-1, 13A UK Plug |
Outlet Type | BS 1363-2 UK Socket Outlet ×8 |
Switch Type | Blue Double-Pole Switch with Cover ×1 |
Overload Protection | Overload Protection Device |
Power Cord | 1.5 mm², 3-Conductor, 2 m |
Cable Entry | Left Entry |
Internal Wiring | Internal wiring shall be securely fastened and properly insulated. |
Electrical Connections | All electrical connections shall be securely terminated. |
UKCA Compliance | Meets applicable UKCA conformity assessment requirements for the Great Britain market; UKCA marking shall be applied where required. |
Yes. The PDU includes an overload protection device designed to provide protection when the connected load exceeds the specified capacity. The total load should still be kept within the 13A maximum rating.
The main housing is made from 6063-T5 aluminium alloy and finished with an eco-friendly powder coating. The metal enclosure provides a structured housing design for indoor power distribution applications.
The standard configuration features a black aluminium housing with green high-strength PC side covers. Custom colours can be discussed for OEM and ODM projects.
The PDU is rated at 250V AC, 13A maximum and 50Hz. The total connected load must not exceed the specified 13A maximum rating.
This model is intended for indoor applications. It should not be used in wet or exposed environments outside the product's specified operating conditions.
Before use, check the PDU and power cord for visible damage, confirm that the product is properly earthed, and make sure the total connected load does not exceed 13A. Do not use the PDU outside its specified operating conditions.